Novomorphic

Article

Why FPGA for adaptive control

Parallel paths, fixed timing.

7 min read

Determinism, parallel datapaths and fast protection. And an honest account of when an MCU is the better answer.

Article by Novomorphic engineeringReviewed by Technical review, Novomorphic

FPGA FABRICTiles, columns, one routeLogic, DSP and block RAM in columns; the path that matters is routed first.DSPBlock RAMDSPLogic tileDSP sliceBlock RAMIO ringRouted pathSOURCE TO SINK
Fig. 1: FPGA fabric

Summary

An FPGA is a cost. It has to buy something a processor cannot.

A modern real-time microcontroller is a remarkable thing. It runs a motor control loop at tens of kilohertz, samples sixteen-bit converters at over a million samples per second, and costs a few pounds. Most drives, most sensors and most controllers should be built on one, and most of ours are. An FPGA costs more, needs a different kind of engineer, and takes longer to change.

So the question is never “FPGA or MCU” in the abstract. It is whether the application needs one of three things a sequential processor cannot provide: timing fixed to the clock cycle, several real-time functions running genuinely in parallel, or a protection response in nanoseconds. When it needs one of them, the FPGA is cheaper than the alternative, which is a system that nearly works. When it needs none, buy the microcontroller.

This article gives the numbers on both sides, a decision procedure we use with customers, and the pattern we use to put an adaptive layer beside a control loop without letting it touch the loop.

What the microcontroller does well

Two hundred megahertz, floating point and a free accelerator

Take a representative part. Texas Instruments’ TMS320F28379D runs two 32-bit cores at 200 MHz with hardware floating point, two independent control-law accelerators also at 200 MHz, up to four 16-bit ADCs at 1.1 MSPS each, 24 PWM channels including 16 with high-resolution timing, and encoder and capture peripherals. A field-oriented control loop at 20 kHz leaves it mostly idle. A loop at 50 kHz is comfortable. The toolchain is mature, the reference designs are plentiful, and the engineers who know it are easy to find.

Its limits are structural rather than numerical. A processor executes one instruction stream per core, so every function that shares a core shares its timing. Interrupt latency is small but not zero, and it varies with what else is running. A protection action goes through the same pipeline as everything else. And the loop rate that is comfortable with one motor and one algorithm becomes tight when a second axis, a communications stack and a model-based estimator are added to the same device.

What the fabric does differently

Latency is a count of clock cycles

In programmable logic, a control algorithm is not executed; it is wired. A published FPGA implementation of three-phase field-oriented control reports a total latency of 84 clock cycles and a new result every 72 cycles, at 100 MHz on a Zynq-7020, using 1,014 flip-flops and 1,245 look-up tables. That is under a microsecond from samples to duty cycles, and it is the same microsecond every time, because nothing else is sharing the pipeline. Adding a second axis does not slow the first; it uses more fabric.

The same property gives fast protection. An over-current comparator feeding a PWM shutdown in fabric reacts in a few clock cycles, not an interrupt latency, and its reaction does not depend on what the processor was doing. Sensor acquisition across several channels can be aligned to the nanosecond. Protocol engines, filters, estimators and the control law each get their own hardware, which is what “parallel” means in this context.

Compare this with a general-purpose processor running real-time Linux. The Open Source Automation Development Lab measures scheduling latency continuously across a farm of systems; a well-tuned machine shows a worst case around 50 to 70 µs, and a single misconfigured kernel option can push it beyond 300 µs. For a 100 ms SCADA loop that is irrelevant. For a 20 kHz current loop, 50 µs is the whole period.

DETERMINISMEdges that wander, edges that holdA processor switches near the clock edge. FPGA logic switches on it, every cycle.SAME CLOCKCH1ProcessorEdges wanderCH2FPGA logicEdges fixed0102030405060 µsEDGE TIMINGEarlyLateEarlyLateLive traceEarlier sweepsEdge wanderNominal clock edge
Fig. 2: Scope trace. What determinism looks like on a scope: the fabric path lands in the same place every cycle, while the software path lands in a band whose width is the jitter.

Side by side

The trade-offs, honestly

Loop latency and jitter

Real-time MCU
Microseconds, with interrupt jitter that grows with load
FPGA or SoC FPGA
Sub-microsecond, fixed at compile time

Parallel functions

Several control, sensing and protocol tasks at once.

Real-time MCU
Time-sliced on one or two cores
FPGA or SoC FPGA
Each in its own logic, independent timing

Protection response

Over-current, desaturation, over-voltage.

Real-time MCU
Hardware trip zones help; software paths add latency
FPGA or SoC FPGA
A few clock cycles, independent of the processor

Unit cost

Real-time MCU
Pounds to tens of pounds
FPGA or SoC FPGA
Tens to hundreds of pounds

Engineering cost and change

Real-time MCU
Lower; C and mature toolchains; quick to iterate
FPGA or SoC FPGA
Higher; RTL or HLS, timing closure, longer iterations

Lifecycle

Availability over a fifteen-year deployment.

Real-time MCU
Good for mainstream families
FPGA or SoC FPGA
Typically long; design is portable between devices

Route to silicon

Real-time MCU
Not applicable
FPGA or SoC FPGA
A direct path to an ASIC when volume justifies it

The decision procedure

Six questions, in this order

  1. What is the fastest loop, and what jitter can it tolerate?

    A current loop at 20 kHz with a 5 µs jitter budget is MCU territory. A 100 kHz loop with a sub-microsecond budget is not.

  2. How many real-time functions run at once?

    One axis and one protocol: processor. Several axes, acquisition alignment, a protocol engine and an estimator: fabric, or a fabric beside a processor.

  3. How fast must protection act?

    If a late trip costs a power stage or a person, the trip path should not pass through software.

  4. What are the interfaces?

    Standard buses and a few ADCs favour the MCU. Many high-rate converters, custom serial links or deterministic Ethernet favour fabric.

  5. What is the lifecycle?

    A product fielded for fifteen years needs a device that will still be made and a design that can move if it is not.

  6. Is there an adaptive layer, and must it be kept away from the control loop?

    If yes, the partition itself is a reason for fabric: the loop and the adaptation can be separate hardware with a defined, bounded interface.

Adaptive, safely

The adaptive layer suggests. The control loop decides.

Adaptive intelligence in a machine means a model running beside the controller, estimating state and parameters from the sensors and proposing changes: a gain, a dead time, a setpoint. The temptation is to let it write directly to the loop. The architecture we use does not. The primary control loop runs in its own logic with its own timing and its own protection. The adaptive layer produces bounded suggestions through a defined interface, and a supervisor decides whether and how fast to apply them.

This is the supplementary-layer pattern, and it matters for three reasons. The deterministic loop keeps its timing regardless of what the model is doing. The safety argument stays small, because the part that has to be argued about is the loop and the bound, not the model. And an assessor working to IEC 61508 can see the boundary in the hardware rather than in a diagram. The fabric is what makes the boundary a fact rather than a convention. On a single processor the two share everything.

This is concept and design-specification work at Novomorphic today. We do not quote an efficiency or performance improvement for it, and we will not quote one for a customer’s machine before seeing their data.

When the MCU is the better answer

Most of the time, and here is how to tell

  • One motor, a loop at or below about 20 to 30 kHz, and standard protection: a real-time MCU with its trip zones does this well and cheaply.

  • A product whose main cost pressure is unit price at volume and whose timing requirement is comfortable: the FPGA will never pay back.

  • A team that knows C and does not know RTL, with no appetite to change: the engineering risk of the fabric outweighs its benefit.

  • An application where the adaptive layer is advisory and offline, so the partition argument does not apply.

The honest middle ground is the SoC FPGA: a processor for the software, fabric for the deterministic path, on one device. Much of our work sits there, and our FPGA proof-of-concept engagements end with a written assessment of whether the result should stay on an FPGA, move to an MCU, or go to silicon.

What this does not prove

Fabric fixes timing, not design quality

A deterministic datapath with the wrong algorithm is deterministically wrong. An FPGA does not make an estimator accurate or a control law stable; it makes their timing predictable. Timing closure, verification and the test bench are where the engineering effort goes, and they are the reason FPGA programmes take longer than they first appear.

The published numbers above are from the cited implementations and the cited measurement farm. They are not Novomorphic measurements.

Sources (7)Every external fact above is cited here so it can be checked rather than believed.

Keep reading

More on System architecture

All insights

Talk to the engineer, not the account manager

Tell us what you are building. We will put you in front of whoever actually knows the answer.

What happens next

1

An engineer reads it

Not a form-handler. Whoever owns the relevant discipline.

2

We come back with a technical view

Including if we think you do not need us.

3

If it looks like a fit, a short technical call

Then, if it is useful, a scoped workshop, feasibility study or evaluation.