Novomorphic

Tool

Engineering calculators

dBm, ENOB and junction temperature, fast.

Instant

Use the tool

TOOL · ENGINEERING CALCULATORS

01

dBm, watts and volts

Convert either way. Type in dBm or in watts, and get the voltage of a sine delivering that power into a load.

Power1 mW
In dBW
-30.00 dBW
RMS voltage
223.6 mV
Peak voltage
316.2 mV
Peak to peak
632.5 mV
FormulaP(W) = 10^((dBm − 30) / 10)V(rms) = √(P × R)V(pk) = √2 × V(rms)
02

SNR and effective bits

What a converter's measured SINAD is worth in bits, what a resolution is worth in dB, and what oversampling adds.

Effective bits from SINAD12.00 bits
Ideal SNR, 16 bits
98.08 dB
Oversampling gain
6.02 dB
Ideal SNR in band
104.10 dB
Equivalent bits in band
17.00 bits
FormulaENOB = (SINAD − 1.76) / 6.02SNR(ideal) = 6.02N + 1.76gain = 10 log₁₀(fs / 2B)
03

Noise figure in cascade

A receiver chain, first stage first. The Friis formula shows why the first stage sets almost everything, and the bar shows the noise figure as each stage is added.

1.00 dB
1.02 dB
1.48 dB
1.84 dB
Cascade noise figure1.84 dB
Cascade gain
41.00 dB
Noise temperature
153.0 K
Sensitivity
-102.2 dBm
FormulaF = F₁ + (F₂ − 1)/G₁ + (F₃ − 1)/(G₁G₂) + …Sensitivity = −174 + NF + 10 log₁₀(B) + SNR
04

Junction temperature

The temperature at the die, through the package, the interface material and the heatsink, and the most power the part can take before it reaches its limit.

Junction temperature80.0 °C70.0 °C of margin
Total thermal resistance
4.00 K/W
Most power at the limit
27.5 W
FormulaTj = Ta + P × (θjc + θcs + θsa)P(max) = (Tj(max) − Ta) / Σθ
05

ADC sizing

Step size, quantisation noise and ideal SNR for a full-scale range and resolution, the slowest sample rate the bandwidth allows, and the bits a dynamic range needs.

Step size, 1 LSB488.3 µV
Quantisation noise
141 µV rms
Ideal SNR, full-scale sine
74.00 dB
Nyquist minimum sample rate
40 kHz
Bits for 90 dB
15 bits
FormulaLSB = FSR / 2ᴺnoise(rms) = LSB / √12fs(min) = 2BN = ⌈(DR − 1.76) / 6.02⌉

Textbook first-order results: a sine at full scale, noise at 290 K, thermal paths in series and steady state. Check anything that matters against your datasheets and a measurement.

When the sums say it should work and the bench says it does not

That gap is where we spend most of our time: signal chains, power stages and thermal paths designed as one system.

Talk to an engineer